Structural Analysis · DTEX CAE

Behind every collapse, a calculation

DTEX CAE is a structural analysis and collapse analysis software developed by DTEX, with all rights owned by DTEX. In silo, chimney and building demolition it calculates, before the blast, which members are to be cut, where the load will be transferred, and in which direction and sequence the structure will collapse.

3,000+Automated tests; same input, same result
5/5NIST TN 1720 laboratory test criteria, in both frame types
20,082blocksİskenderun hospital building model, single run
14Result views; every run is documented in a report

01What it does

From drawing to collapse analysis in one tool

DTEX CAE brings every step of demolition engineering into a single model. Each step is linked to the record of the previous one; every result can be traced back to its source. The program does not decide; it lays out the calculation so that the engineer can.

  1. 01

    Model

    3D model from drawings: columns, beams, shear walls, slabs and reinforcement.

  2. 02

    Structural analysis

    3D frame, buckling and modal analysis; demand/capacity ratio for every member.

  3. 03

    Critical members

    Where the load goes when a load-bearing member is removed, and which members are overstressed.

  4. 04

    Demolition scenario

    Members to be cut, stages and delay sequence, felling direction.

  5. 05

    Collapse analysis

    Separation and collision of members and formation of the debris with AEM, time step by time step.

  6. 06

    Report

    Method statement, technical and client report, reinforcement quantities, summary presentation.

DTEX CAE interface: project tree on the left, 3D view in the centre, run summary on the right, charts below
Fig. 01Interface · modelling, analysis / demolition, reporting

Project tree on the left, 2D/3D view in the centre, run summary on the right, timeline at the bottom.

  • 01

    Turkish-language command line

    Command line and command centre.

  • 02

    Three workspaces

    Modelling, analysis / demolition, reporting.

  • 03

    Autosave

    Every four minutes; recovery after a crash.

  • 04

    Independent solver core

    Solver core independent of the interface; one consistent unit system internally.

02Modelling

From project drawings to a 3D model

Architectural and structural drawings are opened as DXF, DWG or PDF and scaled to true size with two points. Column, beam, wall and slab candidates are recognised automatically; the model does not change until the engineer approves.

DTEX CAE 3D model: the İskenderun hospital building with its columns, beams, walls and slabs
Fig. 02General view · the whole structural system
DTEX CAE: reinforcement in the members and its stress ratio
Fig. 03Reinforcement · reinforcement in the members and its stress ratio
  • MEM

    Members

    Columns, beams, shear walls, slabs; adding storeys and basements, copying storeys.

  • RFT

    Reinforcement

    Beam top/bottom, column longitudinal, stirrup and wall reinforcement; flagged as an assumption in the report when no reinforcement drawing exists.

  • MAT

    Materials

    Reinforced concrete material library: concrete and reinforcing steel grades; properties are calculated from the grade.

  • SUP

    Supports

    Sliding or uplifting supports, loss of ground support.

  • DWG

    Drawings

    Sections, elevations, sheets; DXF and PDF drawing output; reinforcement quantities.

  • SIL

    Silos

    Unrolled silo shell, openings and reinforcement detailing.

03Structural analysis

Demand and capacity for every member

The model is solved as a 3D frame. When a load-bearing member is removed, the redistribution of load is calculated with the alternate load path method, giving a demand/capacity ratio (DCR) for every member. The demand/capacity ratio is the force acting on a member divided by the force it can carry; a member above 1 is overstressed.

  • 01

    3D space frame

    P-Δ effects, buckling and modal analysis; storey drift.

  • 02

    Column capacity

    Column N–M interaction diagram and section capacity.

  • 03

    Beams and walls

    Beam and wall internal forces, punching shear check.

  • 04

    Criticality scan

    The members that govern the stability of the structure.

  • 05

    Before and after

    Automatic before/after removal comparison; load redistribution shares.

Static verdict
Stable · Local risk · Collapse
Dynamic verdict
Stable · Ongoing · Partial collapse · Total collapse
Method
Alternate load path
Output
DCR for every member

Result views

İskenderun hospital building model · removal scenario.

DTEX CAE · Column internal forces

Column internal forces

Axial force and N–M utilisation.

DTEX CAE · Beam internal forces

Beam internal forces

Moment, shear and demand/capacity ratio.

DTEX CAE · Shear wall results

Shear wall results

Wall internal forces and load share.

DTEX CAE · Criticality map

Criticality map

The governing members in a removal scenario.

DTEX CAE · Load redistribution

Load redistribution

Transfer of the removed member’s load to its neighbours.

DTEX CAE · Zone of influence

Zone of influence

Members affected by the removal and their level of criticality.

04Demolition scenario

Which member, in what order, and when?

The scenario is built from the members to be cut and the delays. At every stage you see what load-bearing system the structure has left; a removal sequence can be suggested from the demand/capacity ratios.

  • REM

    Removal

    Sudden, staged, static or dynamic removal.

  • STR

    Strip

    Strip removal by base gap and strip length; slab zones and wall strips.

  • IMP

    Implosion

    Time-delayed implosion plan; staged removal in 3D.

  • FEL

    Felling

    Directional felling of silos and chimneys; felling sequence for silo batteries.

  • LDP

    Load path

    Which columns take the load of the removed column.

  • SHR

    Shoring

    Temporary shoring and equipment loads enter the scenario.

Visual timeline

Playback · collapse frame by frame · two moments side by side.

DTEX CAE · t = 0 s
t = 0 s
DTEX CAE · t = 2 s
t = 2 s
DTEX CAE · t = 3.2 s
t = 3.2 s
DTEX CAE · t = 4.4 s
t = 4.4 s
DTEX CAE · t = 6 s
t = 6 s
DTEX CAE: timeline and collapse sequence frames
Fig. 04At every stage you see what remains of the structure and follow where the load path runs.

05AEM collapse analysis

The structure separates, collides and settles

The Applied Element Method (AEM) models the structure as blocks connected by springs. As springs fail, members separate; blocks collide with each other and with the ground. Cracking, rebar rupture, storeys pancaking onto each other and the formation of debris are followed time step by time step.

Collapse analysisOrbiting camera around the modelİskenderun hospital building · run R2 · 12.0 s model time
20,082Blocks · discrete elements forming the structure
287,992Springs · concrete and reinforcement links
1,551,206Time steps
≈190hComputing time for a single run
  • BLK

    Block–spring

    Separate constitutive laws for concrete and steel; bond–slip and rebar rupture.

  • CNT

    Contact

    Block–block and block–ground collision.

  • SLB

    Slabs

    Slab blocks: storeys pancaking and rubble behaviour.

  • HNG

    Hinges

    Plastic hinge stages are stored in the record.

  • DEB

    Debris

    Debris panel: spread, direction, pile height.

  • REC

    Record

    Time series and energy log; frame sequence and video output.

Collapse analysis views

İskenderun hospital building model.

DTEX CAE · Concrete damage / cracking

Concrete damage / cracking

How damage spreads through the members.

DTEX CAE · Plastic hinges

Plastic hinges

Points where the section reaches yield.

DTEX CAE · Reinforcement stress

Reinforcement stress

Bars approaching yield and rupture.

DTEX CAE · Displacement

Displacement

The movement of every member during the collapse.

06In the field · İskenderun

Same camera, same second

The blast of the hospital building in İskenderun was recorded by drone. When the DTEX CAE model of the same building is played from the field camera’s angle and in real time, the collapse direction matches the field footage.

Same camera, same secondLeft: field · right: DTEX CAE model · real timeİskenderun · 2023 · nearest building 7 m
Quantity compared
Collapse direction
Quantity compared
Movement of the roof edge
Playback
Real-time match

Model output; field back-analysis. The comparison is visual and does not replace experimental validation at building scale. The software does not replace review by a competent engineer or field measurement; it supports them.

07Validation

Compared with tests, every result traceable

The AEM solver was compared with laboratory tests on reinforced concrete beam–column frames in which the middle column was removed (NIST TN 1720). Model parameters were not fitted to the test curves. In both frame types, five out of five criteria fell within the acceptance band.

5/5Intermediate moment frame · criteria within the acceptance band
5/5Special moment frame · criteria within the acceptance band
24Validation runs
Intermediate moment frameSpecial moment frame
CriterionDTEX CAETestDiff.DTEX CAETestDiff.
Catenary peak loadkN569.0547+4.0%1108.41232−10.0%
Catenary displacementmm1117.91092+2.4%1103.31219−9.5%
First peak loadkN313.9296+6.0%828.9903−8.2%

Scope. The scope is the beam–column subsystem; the special moment frame result is obtained within a specific mesh range. This is not experimental validation at building scale. Catenary: the stage in which, after the middle column is removed, the beams carry load in tension like a cable.

Quality and traceability

Same input, same result.

  • 01

    More than 3,000 automated tests

    Every version passes the test suite.

  • 02

    Reproducible results

    Bit-for-bit reproducible results with locked package versions.

  • 03

    Sealed records

    Run records and field observations are sealed with SHA-256.

  • 04

    Expectations first

    Expectations are written down before the calculation; results that miss are recorded too.

  • 05

    Assumptions log

    Limitations that cannot be closed are written in a separate section of the report.

  • 06

    Version trace

    The version number is written into every report and run record.

08Reporting and decision support

The calculation, open to the engineer who decides

Every run is documented as a method statement, a technical report and a client report. Assumptions and limitations are stated plainly in the report; the program never says “removable” — the engineer decides.

DTEX CAE decision support screen: record review
Fig. 05Decision support · record review
  • 01

    Reports

    Method statement; technical and client report (DOCX).

  • 02

    Quantities and presentation

    Reinforcement quantities (XLSX) and summary presentation (PPTX).

  • 03

    14 result views

    Two moments of the same record compared side by side.

  • 04

    Timeline

    Frame sequence and video output.

  • 05

    Decision support

    Measured findings, possible explanations and uncertainties kept separate.

Sample report

İskenderun R2 record review · pages.

DTEX CAE sample report, page 1
DTEX CAE sample report, page 2
DTEX CAE sample report, page 3
DTEX CAE sample report, page 6

09Who it is for

One calculation for every side of a demolition

Building owners and contractors

Method, sequence and collapse direction for silo, chimney and building demolition, reported before the blast.

Public authorities

Calculation-backed demolition methods for technical specifications and tender preparation.

Engineering firms

Analysis services from DTEX for alternate load path and critical member assessment.

DTEX CAE analyses are carried out as part of DTEX engineering services; the results feed directly into the demolition design and the work on site.

How we work

From drawing to site.

  1. 01

    Project and drawings

    Location, drawings and schedule are shared.

  2. 02

    Model and structural analysis

    The 3D model is built and members are checked.

  3. 03

    Demolition scenario

    Cuts, stages and delay sequence.

  4. 04

    AEM collapse analysis

    Collapse direction, sequence and debris area.

  5. 05

    Report

    Technical and client report.

  6. 06

    Execution and recording on site

    Blast, measurement and comparison with the field record.

From analysis to blast, on our own record

—FAQ

Frequently asked questions

Which software do you use?

DTEX CAE, our own software. All rights are owned by DTEX; structural analysis uses a 3D frame and collapse analysis the Applied Element Method (AEM).

Can DTEX CAE be purchased or licensed?

No. DTEX CAE analyses are carried out as part of DTEX engineering services and feed directly into the demolition design.

Does it calculate vibration too?

No; DTEX CAE has no vibration (PPV) module. Vibration and air overpressure are measured on site by seismograph at every blast: Seismic Analysis.

Can an old building without reinforcement drawings be analysed?

Yes. Where reinforcement data is missing, the adopted value is flagged as an assumption in the report and verified by field survey.

How reliable is the result?

The solver was compared with the NIST TN 1720 laboratory tests; five out of five criteria within the acceptance band in both frame types. This applies to the beam–column subsystem and is not experimental validation at building scale. Assumptions and limitations are written separately in the report.

Do you provide a stability report?

Yes; the current condition of the structure and the blasting risks before demolition are reported in a stability report and risk analysis.

Work with us

Let’s start your project with a calculation

Share the location, drawings and schedule of the structure; let’s define the demolition method together with DTEX CAE.

  • 013D model and structural analysis from project drawings
  • 02Demolition scenario and AEM collapse analysis
  • 03Technical and client report
  • 04Technical specification and tender consultancy